CALL NOW :
Electrical Engineering : +91 8467024957 Solar Engineering : +91 753 1923094 Mechanical Engineering: +91 7557688665 Strucutre Engineering : +91 8467024957 Ugc Net: +91 9971409154

Online Power System Protection and Relay coordination Design Training Training Course

Advance Group of Institutiton is India1s Reputed goverment Training Institute which is providing Core Design Training on bsp;   Online Power System Protection and Relay coordination Design Training .               

Online Power System Protection and Relay coordination Design Training Training Course

Advance Group of Engineering Institute is Reputed and Govrement award winining Engineering Institute providing Latest Trend and technology Training on Online Power System Protection and Relay coordination Design Training Training Course and Calculations which is driving significant excitement across the energy sector. Due to the changing electricity landscape and increasing penetration of variable renewable technology capacity, Online Battery Energy System Design has become of particular interest in this emerging industry.

Advance Group of Enigneering Institute specializes in online Electrical Engineering course like Online Power System Protection And Relay Coordination Training.

This program involves leading experts with highly complementary skills in fields such as :, Power System Protection and Relay coordination Design Training Training Course

  • Introduction to power system protection and (ANSI Code of relay )
  • Power system Protection concepts (Type of protection)
  • Power System Protection philosophies
  • Short-circuit calculations (Ohmic Methodology / Per Unit Calculation (IEC 60909/ IEEE 242 :1986))
  • .
  • Instrument Transformer (CT’s, PT’s) selection & application
  • Ground fault protection calculation and Criteria for setting pickups and time dial (TMS and PMS)for DMT and IDMT relays
  • Step by step relay setting and co-ordination exercise for ground fault relays
  • Employment Opportunities

    For Career growth and Job Opportunities in Power System Protection and Relay coordination Design as Design Engineer having Large number apportunies in India also oversea countries Like Dubai, UAE,Oman,Dubai, United Arab Emirates,Kuwait,Qatar,Lagos,Port Harcourt, Nigeria,Catanauan, Philippines,Hobart, Australia,Cape Town,South Africa,Abingdon, United Kingdom,Kenya,Quatre Bornes, Mauritius,Hampton, United States,Padova, Italy,Hamilton, Canada,Shanghai, China,Ovalle, Chile,Singapore,Port Moresby, Papua New Guinea,Petaling Jaya, Malaysia,Beirut, Lebanon,Zimbabwe,Bangladesh,Bahrain,Iraq,Netherlands,Duisburg, Germany,Accra, Ghana,Imsida, Malta,Boudoukha, Algeria,Sweden,Bangkok, Thailand,Medellín, Colombia,SriLanka,Afghanistan,Philippines,Mozambique,Botswana,Uganda . and Companies like Renew Power,Siemens pvt, Electrolyser Stack Design pvt, Aarvi Encon Pvt Ltd Etc.

Chapter 1- Introduction to power system protection and (ANSI Code of relay )

Chapter 2- Power system Protection concepts (Type of protection)

Chapter 3- Power System Protection philosophies

Chapter 4- Short-circuit calculations (Ohmic Methodology / Per Unit Calculation (IEC 60909/ IEEE 242 :1986))

Chapter 5- Instrument Transformer (CT’s, PT’s) selection & application

Chapter 6- Ground fault protection calculation and Criteria for setting pickups and time dial (TMS and PMS)for DMT and IDMT relays

Chapter 7- Step by step relay setting and co-ordination exercise for ground fault relays

Chapter 8- Ground fault relay (ABB , Alstom (MICOM), SIEMENS Relay setting and concept review

Chapter 9- Protection against Overload; Overload v/s overcurrent, Overload capability, Short Circuit Protection; Phase overcurrent and Ground overcurrent Protection, Grounding of transformer neutral. Transformer internal faults (buchholz relay, Winding Relay, Oil relay, MOG, OSR, Over flux etc)

Chapter 10- REF & Differential Protection for Transformer ; Comparison of REF and Differential Schemes, Application of REF protection , REF scheme

Chapter 11- Transformer Differential Protection scheme, Differential Scheme for Three Winding Transformer, CT Specification for Differential and REF applications

Chapter 12- Bus bar protection, Overcurrent , earth fault , differential protection and type of bus bar protection

Chapter 13- Selection of bus bar relay, busbar relay calculation , setting of relays

Chapter 14- Incoming and Outgoing feeder Relay selection Bus coupler Relay Setting

Chapter 15- Generator protection: Plain over current and voltage restrained over current protections, differential, REF

Chapter 16- Distance relay (Device 21) application and principles

Chapter 17- Distance Relay type (Mho, Impedance Relay ), Calculation of distance relay

Chapter 18- Selection of distance relay and setting of ABB, Alstom relays

Chapter 19- Communication of distance and differential relays

Chapter 20- Upstream and downstream relay coordination, breaker and relay tripping setting , protection zone selection

Chapter 21- Overview of O&M of relays

Regular Batch

Duration: Two Months
Schedule : Weekend and Weekdays

Weekend Batch

Duration: Two Months

Schedule: Saturday and Sunday

Only Sunday Batch

Duration:Three Months
Schedule: Sunday